How to connect the current transformer

Current transformer is an instrument that changes the large current in the primary circuit into the small current that can be measured by the secondary ammeter. It is mainly used for current monitoring and measurement or measuring electric energy.


The monitoring and measurement of current can be divided into two forms: one is to detect the current with an ammeter; The other is thermal overload protection measurement.

The wiring method of current detection by ammeter is shown in the following figure:

How to connect the current transformer 1

The P1 terminal of the current transformer in the figure is connected with the A1 terminal of the ammeter, and the A2 terminal is connected in series and grounded with the P2 terminal of the transformer.


How to short circuit other unused transformers?

As we all know, the secondary side of current transformer must not be opened. Because the current transformer is a step-up transformer, in the open circuit state, the secondary side will produce high voltage, which is easy to cause electric shock to human body. Therefore, the secondary side must be short circuited when not in use. The simplest method is to connect P1 and P2 ends directly with 2.5mm wires.


How to exchange P1 and P2 after they are terminated reversely?

When P1 is terminated at P2, connect P1 and P2 back to their original positions.

Transmart. is committed to the R & D, production and sales of amorphous, nanocrystalline and permalloy magnetic core products. Its main products include: nanocrystalline strip, ultramicrocrystalline iron core, ultramicrocrystalline magnetic core, permalloy magnetic core, high-power transformer iron core, nanocrystalline magnetic ring inductance, electromagnetic ring coil, open and close transformer, common mode inductance coil Precision current transformers and other products have the advantages of good stability and high electrical parameters.

prev
Current transformer related problems and Solutions
Reasonable selection of transformation ratio of current transformer
next
Recommended for you
no data
Get in touch with us
Tel: +86 757 8622 8688
Mobile( WhatsApp): +86 139 2868 9494
Email: sales@transmart.net

Address
Room 1113, Block 7, TianAn Center,
31 East Jihua Road, Foshan 528200, China
Better Touch Better Business
Contact Sales at TRANSMART.
+86 757 8622 8688
Copyright © 2026 TRANSMART INDUSTRIAL LIMITED | Sitemap  | Privacy Policy
Customer service
detect